INSTALLATION, OPERATION AND MAINTENANCE MANUAL
WALL EXHAUST FANS BELT & DIRECT DRIVE
XB, HV, HVA, HVAR, ADD, ADDR, DDS, DDP
The purpose of this manual is to aid in the proper installation and operation of the
fans. These instructions are intended to supplement good general practices and are
not intended to cover detailed instruction procedures. It is the responsibility of the
purchaser to assure that the installation and maintenance of this equipment is handled
by qualified personnel.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY
DAMAGE ON THE CARRIER’S BILL OF LADING AND FILE A CLAIM
IMMEDIATELY WITH THE FREIGHT COMPANY.
INSTALLATION
1. Cut and frame the appropriate wall opening. Fans mounted to a wall require a
different wall opening than fans mounted in cabinets or sleeves. For specific
dimensions, refer to the submittal drawing for the specific fan configuration.
2. Mount the fan in the opening with the fan panel directly over the load bearing
support and if this is not practical angle supports must be provided to transfer
the fan weight to the load bearing structure.
3. Caution: The fan contains rotating parts and requires electrical service.
Appropriate safety precautions should be taken during installation, operation
and maintenance.
4. Warning: Do not install or operate this fan in an environment where
combustible materials, gasses or fumes are present unless it was specifically
designed and manufactured for that application.
5. A damper, if used, should be securely mounted in a manner that allows free
and unobstructed operation.
6. All electrical work must be done, in accordance with all applicable electrical
codes, by a qualified electrician.
7. Prior to wiring ensure the power supply is locked in the OFF position and that
the motor nameplate voltage and the supply voltage match.
M0112 – XB,HV,HVA,HVAR,ADD,ADDR,DDS,DDP
1
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, HVAR, ADD,

Seite 2

M0112 – XB,HV,HVA,HVAR,ADD,ADDR,DDS,DDP 10

Seite 3 - MAINTENANCE

M0112 – XB,HV,HVA,HVAR,ADD,ADDR,DDS,DDP 2 8. Be sure to keep all wiring clear of any rotating parts. 9. Before starting the fan ensure that the wh

Seite 4

M0112 – XB,HV,HVA,HVAR,ADD,ADDR,DDS,DDP 3 Typical Installation Refer to page 8 Start Up Turn the fan on and inspect for the following. • Direction

Seite 5 - Pulley Alignment

• The standard pillow blocks on belt driven fans are factory lubricated. These bearings should be lubricated on a semi annual basis (more frequently

Seite 6 - FAN ASSEMBLY

Pulley Alignment INCORRECTINCORRECTINCORRECTCORRECT Recommended Torque for Setscrews/Bolts (inch/lbs) M0112 – XB,HV,HVA,HVAR,ADD,ADDR,DDS,DDP

Seite 7

• Tighten the bearing bolts to the proper torque rating (see chart) • Turn the propeller by hand the propeller should rotate freely with the same

Seite 8 - BY OTHERS

M0112 – XB,HV,HVA,HVAR,ADD,ADDR,DDS,DDP 7 FAN TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE CAUSES

Seite 9 - December 2011

TYPICAL INSTALLATIONS Wall exhaust fan with cabinet, back guard and shutter The drawin

Seite 10

ADDR & HVAR FANS Please note for the reversing models ADDR, HVAR, the supplied reversing switch should be wired in accordance with the instruct